    Modbus Gateway

    • 1-port Modbus gateway
    • 1-port Modbus gateway
    • 1-port Modbus gateway
    • 1-port Modbus gateway
    1-port Modbus gateway1-port Modbus gateway1-port Modbus gateway1-port Modbus gateway

    1-port Modbus gateway

    • Model:ADM-5850G
    • Interface: RS-485/422/232,10/100MEthernet
    • Protocol: MODBUS-RTU/ASCII,MODBUS-TCP
    • Supply voltage: DC9~48V@3W Max
    • Product description: ADM-5850G is an industrial Modbus gateway device, the user can easily use it to seamlessly integrate Modbus Ethernet devices and Modbus serial port device, DIN rail installation, DC9-48V power supply,
    • INQUIRY

    Functional introduction

    The Modbus protocol is the most widely used protocol in the electronic industrial equipment, and now it has become a general industrial standard. Through this protocol, Modbus devices (such as PLC, DCS, HMI, and instruments) can communicate with each other through a network or serial port. But the Modbus protocol used in the serial port and the Ethernet network is different, so a gateway is needed to complete the communication conversion between the two protocols. ADM-5850Gis a modbus gateway product dedicated to connecting Modbus TCP devices and Modbus RTU/ASCII devices.

    ADM-5850Ghas Modbus RTU/ASCII and Modbus TCP protocol conversion functions, it integrates Modbus TCP, Modbus RTU and Modbus ASCII protocol, and the device's serial port can be configured by software of RS-232, RS-485 or RS-422, you can easily achieve Modbus Ethernet devices with Modbus serial devices connected.

    Product features

    1, 32 bit ARM Cortex-m3 CPU

    2, 1 Port 10/100MEthernet interface

    3, Support RS-232, RS-422, RS-485 serial port mode

    4. Baud rate, Data bit, Stop bit, Parity bit can be set

    5. Integrated ARP, IP, ICMP, IGMP, UDP, TCP, DHCP, DNS,MODBUS TCP, MODBUS RTU, MODBUS ASCII protocol

    6. Provide 4 mode of work:

    RTU_ Master--TCP_ Slaver, TCP_ Master--RTU_ Slaver

    ASCII_ Master--TCP_ Slaver, TCP_ Master--ASCII_ Slaver

    7. Maximum support for 32 Modbus TCP master stations and 4 Modbus TCP slave stations

    8. The automatic adaptive function of the time interval of the character

    9, Provide ID mapping function to realize the management of host ID number

    10. The local port, the target IP address, and the target port number can be set

    11, Can be configured through Web Server, Telnet, MG Configuration tools

    12, MG Configuration tools support

    Windows98/me/NT/2000/XP/WIN7/WIN8/WIN10 operating system

    13, Industrial design, can run steadily in bad environment

    Product specification

    Ethernet

    Standard:  10/100Mbps adaptive Ethernet port

    Communication mode:  full duplex / half duplex adaptive

    Transmission distance:  less than 100 meters

    Interface type:  RJ-45

    Serial port

    RS-232 signals:  TXD, RXD, RTS, CTS, GND

    RS-422 signals:  T+, T-, R+, R-

    RS-485 signal:   D+, D-

    Parity bit:   None\Even\Odd\space\mark

    Data bits:   6bit, 7bit, 8bit

    Baud rate:   300BPS to 230400bps

    Direction control:    RS-485 uses data flow direction automatic control technology

    Load capability:    RS-485/422 terminal support maximum 32 node polling

    Transmission distance:   RS-485/422 is 1000 meters, RS-232 is 10 meters

    Interface protection:   1500W surge protection, 15KV ESD protection

    Interface type:   RS-232 terminal DB-9 male, RS-485/422 terminal

    Power Supply

    Power input:   DC9~48V power supply

    Power consumption:   120mA @ 24V (Max)

    Environmental

    Working temperature:  -20 C~70 C

    Storage temperature:  -40 C~95 C

    Storage humidity:   5 ~ 95% RH

    Package size

    Long x wide x high:   103x72x27 (mm)

    Interface definition

    RS-232:DB9 male head (TXD, RXD, RTS, CTS, GND)

    RS-422: terminal (T+, T-, R+, R-)

    RS-485: terminal (D+, D-)

    Network interface: RJ45 (Ethernet)

    Power interface: terminal VS+, VS-

    Restore the default settings

    Hardware recovery:   Setup and GND short connection, the gateway reboot, and then disconnect Setup and GND, to restore the default settings.

    Software recovery:    Search the device through the MG Configuration tool software and click to restore the factory settings button.

    LED instructions

    Power indication:   "PWR" bright red is the normal power supply

    Modbus TCP connection success indication:   "Active" is bright green

    Serial data sending and receiving indication:   "TX/RX" is Flash